• P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit
  • P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit
  • P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit

P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit

Type: IVD Reagent
Spec: 32T
Transport Package: Paper Carton with Icy Bag
Specification: 44*44*45 cm
Trademark: Tianlong
Origin: Suzhou Shaanxi
Samples:
US$ 100/Box 1 Box(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
P118H
HS Code
3822009000
Production Capacity
5000000 Test/Year

Product Description

Product Name: 
Human Leukocyte Antigen B27 Nucleic Acid Detection Kit (Fluorescence PCR Method)

 
Spec: 
32T/Kit

Intended Use:
The kit is used for in vitro quantitative detection of human leukocyte antigen B27 gene (including B2702, B2704, and B2705 subtypes) in human whole blood samples.

Ankylosing spondylitis (AS) is a rheumatic disease characterized by the involvement of the central axis and peripheral joints, and chronic inflammation and the formation of new bones. The disease is more common in adolescents. Severe joint dysfunction can occur within 10 years of onset. When the spine, sacroiliac joints and hip joints develop lesions, the lesions are irreversible. Among them, human leukocyte antigen-B27 (HLA-B27) is considered to have a strong correlation with AS, that is, the positive rate of HLA-B27 in AS patients is as high as 90%. The kit developed by our company can detect the B2702, B2704, and B2705 subtypes related to AS, but it cannot distinguish between different genotypes. The test results of this kit are for the auxiliary diagnosis of AS. The test results shall not be used as the only indicator of the patient's condition evaluation. The patient's clinical manifestations and other testing methods must be combined to make a comprehensive analysis of the condition.

Principle of Test:
A pair of HLA-B27 specific primers are selected and combined with specific probes. The probes can specifically bind to a DNA template in the middle of the primer amplification region. In the process of PCR extension, the exonuclease activity of Taq enzyme will cut off the 5'end fluorescent groups from the probes, freeing them in the reaction system, thus breaking away from the shielding of the 3'end fluorescence quenching groups, which can receive light stimulation and emit fluorescence that can be detected by the instrument, this kit uses FAM channel, so as to achieve the automatic detection of HLA-B27 nucleic acid in closed reaction system.

A pair of housekeeping gene-specific primers are selected as the internal standard in the kit and combined with specific probes. The probes can specifically bind to a DNA template in the middle of the primer amplification region. In the process of PCR extension, the exonuclease activity of Taq enzyme will cut off the 5'end fluorescent groups from the probes, freeing them in the reaction system, thus breaking away from the shielding of the 3'end fluorescence quenching groups, which can receive light stimulation and emit fluorescence that can be detected by the instrument, The internal control adopts VIC channel, so as to realize the detection process monitoring in closed reaction system, which can effectively monitor the occurrence of false negatives.

Storage Condition & Validity:
All reagents should be stored at -20ºC±5 ºC. The validity period of the reagents is 12 months.

Applicable Instrument: 
Gentier 96E real time PCR system and Gentier 96R real time PCR system, TL988-IV real time PCR system, ABI7500 real time PCR systems
 
Sample Requirements :
1. Sample: human whole blood samples.
2. Collection: 3~5mL of venous blood is extracted from the subject with a disposable sterile syringe, and injected into a glass tube containing EDTA
   
anticoagulant. The glass tube is immediately reversed gently and mixed for 5~10 times, so that the anticoagulant and venous blood are fully mixed.
3. Storage: samples can be stored at 2~8ºC for no more than 24 hours; under -20ºC for no more than 3 months; under -70ºC for long-time, but
    repeated freeze-thaw should be
 avoided.
4. Transportation: It is transported in a foam box with ice to seal for transportation.
Tianlong Real Time PCR Test Kit Catalogue:
P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection KitP118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit

Tianlong Product Solution:
P118H - Human Leukocyte Antigen B27 Nucleic Acid Detection Kit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
62020000 RMB
Plant Area
20000 square meters