Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | PCR Thermal Cycler |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Genesy96T is a new generation of gene amplification thermal cycler independently developed by Tianlong, with innovative design, intelligent and friendly user operating system, fast and accurate temperature control and a variety of practical functions for your applications.
* 7-inch TFT color touch screen, easy to operate;
* Rapid heating up and cooling down, accurate temperature control, for reliable results;
* 12 temperature gradients to meet diverse needs;
Item
|
Parameter
|
Product Model
|
Genesy 96T
|
Authoritative Certifications
|
NMPA, CE, etc.
|
Suitable Consumables
|
0.2mL single tubes, 0.2mL 8-tube strips, 0.2mL skirted / semi-skirted / skirtless 96-well plates.
|
Reaction Systems
|
0~100μL
|
Module Temperature Range
|
4.0 ºC ~ 99.9 ºC
|
Temperature Control Mode
|
Tube Mode, Block Mode
|
Gradient Module
|
Up to 12 gradients in one run
|
Gradient Temperature Span
|
1 ~ 40 ºC
|
Gradient Temperature Range
|
35 ~ 100 ºC
|
Temperature Range of Heater Lid
|
40 ~ 110 ºC
|
Temperature Uniformity
|
±0.2 ºC
|
Temperature Accuracy
|
±0.1 ºC
|
Heating & Cooling Rates
|
Up to 5.5ºC/s
|
Steps
|
Unlimited
|
Cycles
|
Up to 99
|
Increment / Decrement Time
|
1s ~ 10min
|
Increment / Decrement Temperature
|
0.1~5 ºC, Touchdown PCR assay available
|
Program Storage
|
> 1000 sets
|
UI
|
7-inch TFT true-color LCD touchscreen, 800×480 resolution
|
Operating Noise
|
<55dB
|
Structural Design
|
The instrument is designed with air ducts in the front and back, for multiple units to be placed closely in parallel to save laboratory space. |
Software
|
1. Beeping alert function; 2. Automatic calculation and display of gradient temperatures for each column; 3. Graphical interface showing PCR running process in real time; 4. Unlimited number of programs with USB storage; 5. Power failure protection: automatic recovery of the experiments when the power is on again after cutting off; 7. Pre-stored standard experiment templates, without tedious programming; 8. One-click start-up of the experimental program, quick and easy; |
Characteristic
|
1. Self-pressurized heater lid with no need to adjust its height, compatible with a variety of consumables; 2. Individual folders available, for quick access to the programs. |
Size and Weight
|
260mm*400mm*260mm(W*D*H),11 kg
|
Power supply
|
AC 100~240 V, 50~60 Hz, 600 VA
|