Customization: | Available |
---|---|
Classification: | Medical Diagnosis Equipment |
Type: | Real-Time PCR System |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
96 samples to be scanned in 7s
Only 7s for all 96 wells of fluorescence scanning can significantly reduce testing time and improve efficiency for lab professionals.
Efficient temperature control
Based on the Peltier heating/colling method, the maximum heating ramp rate is >6.1°C/s and the maximum cooling ramp rate is >5.0°C/s.
Power failure protection design
Power failure protection design can recover the experiment automatically, with no more concern about instantaneous power failure.
More convenient with two configurations
Standalone configuration: 10.4-inch touch screen; PC control configuration: PC software control via connection
Powerful software analysis
Gentier 96 E/R offers various data analysis functions, including absolute quantitative analysis, relative quantitative analysis, SNP analysis, melting curve analysis, etc.
Model | Gentier 96T |
Throughput | 1-96 |
Fluorescence Channels | 6 |
Fluorescence Scanning Time | 7s |
Optical System | |
Light Source | High-brightness, long-life and maintenance-free LED light source, excitation from the top |
Detector | Photodiode (PD), top scanning |
Excitation Range | CH1: 465nm CH2:527nm CH3:580nm CH4:632nm CH5:680nm CH6:527nm |
Detection Range | CH1:510nm CH2:563nm CH3:616nm CH 4:664nm CH5:730nm CH6:616nm |
Fluorescence Dynamic Range | Adjustable |
Sample Dynamic Range | 1-1010 copies |
Thermal Block | |
Heating Method | Peltier |
Heating Rate | >6.1°C/s |
Cooling Rate | >5.0°C/s |
Temperature Uniformity | ±0.1ºC |
Temperature Accuracy | ≤0.1ºC |
Gradient Range | 1°C-40°C |
Gradient Block | 12 row |
Special Temperature Protocol | Thermal gradients PCR, Long PCR, Touch Down PCR |
Sample Testing Linearity and Repeatability | Linear Correlation:/r/ >0.999 Repeatability: cycle threshold (Ct) value CV <0.5% |
Software Functions | |
Control Method | Mode 1:10.4 inch touch screen Mode 2:PC direct control |
Power Failure Protection | Automatically start running experiments after power supply, no need to wait PC software |
Data Storage and Transmission | Upload and download through USB disk,1000 results can be stored in machine |
Reporting Function | Templates reserved; customized experiment report |
Key Applications | Relative quantification, absolute quantification, melting curve analysis, SNP analysis |
Others | |
Operating System for PC | Win 7, Win 10 |
Instrument Dimensions | 355mm*475mm*484mm (W*L*H) |
Weight | 30kg (net) |
Power Supply and Power Consumption |
AC 100-240V, 50-60Hz; 900VA |
Suitable Consumables | 0.2 mL 96-well plates, 8-tube strips, single tubes (clear, frosted and white) |